# SDR 2000ZZZX242

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 19, 1999
- Submitted: March 26, 2000
- Operation: General aviation
- Filed by: [Duncan Aviation Inc, repair station JGVR194F](https://openairdocs.org/faa-repair-station/JGVR194F/duncan-aviation-inc.md) (OpenAirDocs)
- System (JASC): [2432 · Battery/Charger System](https://openairdocs.org/jasc/2432)
- Part: Battery
- Part number: G6381E
- Condition: Damaged
- Location: E/E Bay
- Stage of operation: IN
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/2000ZZZX242

## Discrepancy

BATTERY HANDLE HOLD-DOWN BOLTS ARE BEING DETERIORATED BY THE ELECTROLYTE.  SEVERAL BOLTS DISSOLVED TO NOTHING BUT POWDER.  GILL, P/N 1407.  SUBMITTER STATED HAS SEEN PROBLEM ON THREE BATTERIES, GILL P/N G-6381E, SN'S G01806043, G01806051, AND G01806060.  CONTACTED MANUFACTURER AND THEY WERE AWARE OF PROBLEM.

---