# SDR 2005FA0000326

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 5, 2004
- Submitted: March 15, 2005
- Operation: General aviation
- Make and model: Airbus A330*
- System (JASC): [5210 · Passenger/Crew Doors](https://openairdocs.org/jasc/5210)
- Part: Bypass Valve
- Part number: FRM530014D
- Part serial: FR099BD
- Condition: Leaking
- Location: Door
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/2005FA0000326

## Discrepancy

A DOOR BYPASS VALVE WAS RETURNED FOR INVESTIGATION.  THE REASON FOR RETURN WAS ON PUSHBACK, FLIGHT CREW REPORTED GREEN RESERVOIR LOW LEVEL,  WHERE THE INVESTIGATION FOUND A LEAK ON THE DOOR BYPASS VALVE.  INVESTIGATION IDENTIFIED THAT BOLT HAD SHEARED.  FURTHER INVESTIAGATION AT MFG, THAT AN INITIATING FORCE HAD RESULTED IN A CRACK THAT PROPAGATED ACROSS THE BOLT SECTION, RESULTING IN FAILURE.  BOLTS COULD BE YIELDED WHEN TIGHTENED.(K)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.