# SDR 2007UALA01240

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 20, 2007
- Submitted: May 18, 2007
- Operation: Air carrier
- Aircraft: [N662UA](https://openairdocs.org/aircraft/N662UA), registered now
- Make and model: Boeing 767322
- Aircraft serial: 27159
- Aircraft time: 60,726 hours, 9,843 cycles
- Engine: Pwa PW4060
- System (JASC): [2420 · AC Generation System](https://openairdocs.org/jasc/2420)
- Part: Transformer
- Part number: 2B751A
- Condition: Shorted
- Location: Cabin
- Stage of operation: CL
- How discovered: O
- Nature of condition: O
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/2007UALA01240

## Discrepancy

ELECTRICAL POWER PROBS CAUSED RTFL.  REPLACED CURRENT TRANSFORMER T9000.  REF WDM25-31-12, WDM25-31-13, WDM33-31-13 & WDM33-27-12.  RELUGGED WIRE (32-16) AT C9010 W12 DUE TO HEAT DAMAGE.  PERFORMED LOAD TEST AND LOAD SHED TEST OPS CHECKS NORMAL REF GNMM02-0-21-001.  APPLIED POWER TO GALLEY AND TESTED ALL FUNCTIONS.  ALL FUNCTIONS TESTED NORMAL.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.