## Discrepancy

FWD EQUIPMENT OVERHEAT EICAS MESSAGE CAME ON PASSING 10000 FEET AND EXTINGUISHED PASSING 18000 FT.  SUSPECT FAULTY COOLING OVERRIDE VALVE.  REPLACED FWD E&E COOLING OVERRIDE VALVE PER MM 21-58-20.  OPS CHECK OK.  AC OK FOR SERVICE.

---