# SDR 2010FA0000846

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 9, 2010
- Submitted: August 20, 2010
- Operation: General aviation
- Make and model: Doug MD-90-30
- Registry model: [Doug MD-90-30](https://openairdocs.org/model/mcdonnell-douglas-md-90-30) (OpenAirDocs)
- System (JASC): [2421 · AC Generator-Alternator](https://openairdocs.org/jasc/2421)
- Part: Generator
- Part number: 28B5278
- Part serial: 50B0026
- Condition: Failed
- Part time: 10,910 hours
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/2010FA0000846

## Discrepancy

(HZ3R) DISASSEMBLED UNIT AND FOUND THE INSIDE TO BE COMPLETELY VOID OF OIL.  THERE WAS A LARGE AMOUNT OF ALUMINUM INSIDE OF THE FILTER HOUSING.  THE PUMP WAS SEIZED AND THE PUMP BEARING CAGE WAS PROTRUDING FROM THE HOUSING.  THE PUMP DRIVE SHAFT WAS ALSO BROKEN.  THE INSIDE PORTION OF THE STATOR AND THE END BELL WERE INTACT, BUT THE STATOR HAD SEVERE RUB DAMAGE AND BOTH THE STATOR AND THE ENDBELL HAD EXTREME HEAT DAMAGE.  THE ROTOR HAD EXTREME RUB DAMAGE.  THE DRIVE END BEARING WAS IN VERY GOOD CONDITION BUT THE ADE BEARING HAD EXTREMELY BAD WEAR AND HEAT DAMAGE.  THE EXCITER STATOR WAS IN GOOD CONDITION.  BASED ON THE AMOUNT OF ALUMINUM FOUND IN THE FILTER AND THE CONDITION OF THE PUMP, IT IS LIKELY THAT THE PUMP WAS THE FIRST TO FAIL.  PREVENTATIVE ACTION: PENDING COMPLETION OF ENGINEERING INVESTIGATION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.