# SDR 2023FA0000087

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 14, 2023
- Submitted: February 14, 2023
- Operation: General aviation
- Aircraft: [N308MR](https://openairdocs.org/aircraft/N308MR), registered now
- Make and model: Cessna 650
- Registry model: [Cessna 650](https://openairdocs.org/model/cessna-650) (OpenAirDocs)
- Aircraft serial: 650153
- Aircraft time: 7,586 hours, 5,772 cycles
- System (JASC): [2430 · DC Generating System](https://openairdocs.org/jasc/2430)
- Part: Sensor
- Part number: S35979
- Part serial: NA
- Condition: Open
- Location: Zone 100
- Part time: 291 hours, 215 cycles
- Component: Battery, Cessna
- Component part number: S35978
- Stage of operation: TO
- How discovered: V
- Nature of condition: J
- Precautionary procedure: C
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/2023FA0000087

## Discrepancy

ON TAKEOFF ROLL OUT AT LIT NUMBER 2 BATTERY OVERTEMPERATURE ANNUNCIATOR ILLUMINATE . FLIGHT CREW NOTIFY TOWER ABORTED TAKEOFF WHILE TAXI BACK TO FBO CREW CHECKED BATTERY TEMPERATURE GAUGE READING AND TEMPERATURE WAS NORMAL. . INSPECTED BATTERY FOUND NOT OVERHEATED NUMBER 2 BATTERY SYSTEM WAS MEL I/A/W CHOICE AVIATION APPROVED MEL 24-32-01  DISCONNECTED #2 BATTERY AND BAG SECURE CONNECTOR.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.