# SDR 2026F00238

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 28, 2026
- Submitted: October 29, 2026
- Operation: General aviation
- Aircraft: [N791SA](https://openairdocs.org/aircraft/N791SA), registered now
- Make and model: Cndair CL6002B19
- Aircraft serial: 7968
- Aircraft time: 33,630 hours, 32,538 cycles
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Quick Disconnect
- Part number: AE99147E
- Part serial: NSN
- Condition: Cracked
- Location: Zone 400
- Part time: 33,630 hours, 32,538 cycles
- Component: Hyd Engine Pump, Eaton
- Component part number: 887055
- Stage of operation: AP
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/2026F00238

## Discrepancy

ON APPROACH INTO KBED. HYD EDP 2A CAUTION MESSAGE. VIBRATION FELT IN COCKPIT WITH INTERMITTENT HYD 2 LOW PRES. HYDRAULIC SYNOPTIC PAGE SHOW NO FLUID IN SYSTEM 2. PRESSURE NEVER WENT BELOW 2000 PSI SO HYDRAULIC PUMP 2 WAS TURNED ON PER QRH. DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. CFR INSPECTED THE RIGHT ENGINE AFTER LANDING AND OBSERVED NO OBVIOUS DAMAGE. TAXIED TO THE FBO.  REMOVED AND REPLACED NR 2 EDP IN REF TO CRJ 200 AMM 29-11-01. LEAK CHKD GOOD. OPS CHKD GOOD. R & R TUBE ASSY AND QUICK DISCONNECT COUPLING FOR NR 2 SYSTEM IN REF TO AMM 29-11-15. OPS CHECK GOOD. LEAK CHECK GOOD. ACFT OK FOR SVC.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.