# SDR 7C7A2025012300002

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 22, 2025
- Submitted: January 23, 2025
- Operation: Air carrier
- Aircraft: [N891EA](https://openairdocs.org/aircraft/N891EA), registered now
- Make and model: Dhav DHC8106
- Aircraft serial: 335
- Aircraft time: 56,046 hours, 59,410 cycles
- System (JASC): [2997 · Hydraulic Power System Wiring](https://openairdocs.org/jasc/2997)
- Part: Elec Connector
- Part number: 2921P1
- Condition: Dirty
- Location: Hyd Pump
- Stage of operation: CL
- How discovered: O
- Nature of condition: N
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/7C7A2025012300002

## Discrepancy

DISCREPANCY: #1 HYDRAULIC PUMP 'HOT CAUTION' LIGHT FLICKERING ON.  CORRECTIVE ACTION: SWAPPED TO SECONDARY TEMP SENSOR ON #1 SPU AND REPLACED CANNON PLUG 2921-P1 AND OPS CHECKED GOOD IAW DASH-8-100 AMM 29-11-14.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.