# SDR 9520079957

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 10, 1995
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: N915RW
- Make and model: Doug DC-9-31
- Registry model: [Doug DC-9-31](https://openairdocs.org/model/douglas-dc-9-31) (OpenAirDocs)
- Aircraft serial: 47139
- System (JASC): [2824 · Fuel Transfer Valve](https://openairdocs.org/jasc/2824)
- Part: Circuit Breaker
- Condition: Tripped
- Location: Aux Fuel Pump
- Stage of operation: CR
- Nature of condition: O
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/9520079957

## Discrepancy

DURING CRUISE, THE FUEL IN THE AUXILIARY FUEL TANK WOULD NOT TRANSFER.  AIRCRAFT DIVERTED TO MOT TO REFUEL.  RESET CIRCUIT BREAKER FOR AUXILIARY FUEL PUMP.  OPERATIONAL CHECK GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.