# SDR 95ZZZX2412

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 11, 1995
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N8627A](https://openairdocs.org/aircraft/N8627A), registered now
- Make and model: Beech E18S-9700
- Registry model: [Beech E18S-9700](https://openairdocs.org/model/beech-e18s-9700) (OpenAirDocs)
- Aircraft serial: BA283
- System (JASC): [2140 · Heating System](https://openairdocs.org/jasc/2140)
- Part: Resistor
- Condition: Open
- Location: Overheat Probe
- Component: Janitrol, G93A22
- Stage of operation: IN
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/95ZZZX2412

## Discrepancy

HEATER INSPECTION REVEALED THE CORRECT TYPE OF FUSE WAS INSTALLED.  ACTUATION OF THE OVERHEAT PROBE FAILED TO BLOW THE FUSE.  FURTHER INSPECTION REVEALED THAT THE 3 OHM 10 WATT RESISTOR, LOCATED IN THE WIRING BETWEEN THE OVERHEAT PROBE AND THE FUSE, WAS 'OPEN'.  THE RESISTOR WAS REPLACED AND THE SYSTEM FUNCTION TESTED SATISFACTORY.

---