# SDR 95ZZZX2567

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 17, 1995
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: N365WM
- Make and model: Aerosp AS 365 N2
- Registry model: [Aerosp AS 365 N2](https://openairdocs.org/model/aerospatiale-as-365-n2) (OpenAirDocs)
- Aircraft serial: 6429
- System (JASC): [2430 · DC Generating System](https://openairdocs.org/jasc/2430)
- Part: Relay
- Part number: 220010
- Condition: Shorted
- Location: Rev Current
- Part time: 670 hours
- Stage of operation: IN
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/95ZZZX2567

## Discrepancy

REVERSE CURRENT RELAYS SHORTED BY ELECTRICAL PROBLEM IN GENERATOR CIRCUIT TRACED TO EMERGENCY GENERATOR RESET BUTTON.  REMOVED AND REPLACED REVERSE CURRENT RELAYS.  REPLACED 2 EACH.

---