## Discrepancy

ON SECOND TAKEOFF DURING CLIMB, MAN. PRESS. DECAYED TO 27 INCHES HG.  CLIMB CONTINUED AND POWER SLOWLY CAME BACK - NEXT TAKEOFF WAS NORMAL.  REPLACED TURBO CONTROLLER AND ALL HOSES TO AND FROM WASTEGATE, ALSO, CONTROLLER DRAIN HOSE.  A/C RAN TO TEST, APPEARED NORMAL.  MADE TWO TAKEOFFS, FULL POWER, NO DEFECTS NOTED - THIS IS THE THIRD CONTROLLER THIS ENG HAS HAD.  SUBMITTER STATED NOT SURE WHAT CAUSED THE PROBLEM OR IF IT IS CURED.

---