## Discrepancy

MIA/EYW - FLT 103 - LANDING GEAR CIRCUIT BREAKER TRIPPED ON EXTENSION.  RESET AND GEAR CAME DOWN.  DETERMINED HYDRAULIC RESERVOIR CAP PREFORMED PACKING TO BE CUT, REMOVED AND REPLACED PACKING AND SERVICED SYSTEM.  OPS CHECK/LEAK CHECKS GOOD ON JACKS.

---