# SDR 95ZZZZ250

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 23, 1995
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N410EA](https://openairdocs.org/aircraft/N410EA), registered now
- Make and model: Doug DC-9-51
- Registry model: [Doug DC-9-51](https://openairdocs.org/model/mcdonnell-douglas-dc-9-51) (OpenAirDocs)
- Aircraft serial: 47731
- System (JASC): [2161 · Cabin Temperature Controller](https://openairdocs.org/jasc/2161)
- Part: Amplifier
- Part number: 60714622
- Condition: Malfunctioned
- Location: Rt Pack
- Stage of operation: CL
- Nature of condition: B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/95ZZZZ250

## Discrepancy

STL - FLT 518 - DURING CLIMB A SMOKE ODOR APPEARED IN CABIN.  TURNED RIGHT AIR CONDITIONING PACK TO FULL COLD, ODOR AND HAZE DISSIPATED, RETURNED TEMPERATURE CONTROL TO NORMAL RANGE.  REPLACED TEMPERATURE CONTROL AMPLIFIER, (P/N 607146-2-2) AND WATER SEPARATOR COALESCER, (P/N 179460-8-1).  AIR CONDITIONING SYSTEM OPERATION CHECKED NORMAL.  CHECK C-12 - 1-11-95 - STL.  REF 95ZZZZ251.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.