# SDR 9616419918

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 31, 1996
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: N940N
- Make and model: Doug DC-9-32
- Registry model: [Doug DC-9-32](https://openairdocs.org/model/mcdonnell-douglas-dc-9-32) (OpenAirDocs)
- Aircraft serial: 47572
- System (JASC): [4970 · APU Indicating System](https://openairdocs.org/jasc/4970)
- Part: Temp Sensor
- Condition: Malfunctioned
- Location: Lt Pack
- Stage of operation: CL
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/9616419918

## Discrepancy

AUTO PRESSURIZATION SYSTEM FAILED AFTER TAKEOFF.  FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT.  MAINTENANCE REPLACED THE LEFT FLOW CONTROL VALVE WITH NO HELP.  REPLACED THE LEFT PACK TURBINE INLET TEMPERATURE SENSOR.  OPERATIONAL CHECK NORMAL.  AIRCRAFT RETURNED TO SERVICE.

---