# SDR 96FDEA01656

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 7, 1996
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N189FE](https://openairdocs.org/aircraft/N189FE), registered now
- Make and model: Boeing 727-22
- Registry model: [Boeing 727-22](https://openairdocs.org/model/boeing-727-22) (OpenAirDocs)
- Aircraft serial: 19082
- System (JASC): [2424 · AC Regulator](https://openairdocs.org/jasc/2424)
- Part: Gcu
- Condition: Water Contam
- Location: Nr 1 Generator
- Stage of operation: CL
- Nature of condition: H
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/96FDEA01656

## Discrepancy

NR 1 GENERATOR TRIPPED OFF LINE 2-3 MINUTES AFTER TAKEOFF.  BUS TIE WOULD NOT CLOSE PER CHECKLIST.  FINALLY DID CLOSE BUT FIELD WOULD THEN NOT CLOSE WITH GOOD RESIDUAL VOLTS.  REMOVED AND CLEANED WATER FROM GCU.  REINSTALLED, OPS CHECKED NORMAL PER JRH 8-3.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.