## Discrepancy

TOTAL LOSS OF HYDRO SYSTEM NR 3 ON CLIMBOUT, PERFORMED RED TAB PROCEDURE AND LANDED 35/EXT 16L SEA WITHOUT INCIDENT.  MAINTENANCE FOUND 2/3 REVIISABLE MOTOR PUMP LEAKING.  REMOVED AND REPLACED 2/3 REVIISABLE MOTOR PUMP PER M/M 29-22-01, LEAK AND OPS CHECK GOOD.  REMOVED AND REPLACED NR 3 ENG PRESSURE AND CASE DRAIN FILTERS, NO CONTAMINATION NOTED.

---