# SDR 96ZZZX5943

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 19, 1996
- Submitted: March 26, 2000
- Operation: General aviation
- Aircraft: [N35TK](https://openairdocs.org/aircraft/N35TK), registered now
- Make and model: Cessna 425
- Registry model: [Cessna 425](https://openairdocs.org/model/cessna-425) (OpenAirDocs)
- Aircraft serial: 4250088
- System (JASC): [2437 · DC Indicating System](https://openairdocs.org/jasc/2437)
- Part: Switch
- Part number: MTA206R
- Condition: Malfunction
- Location: Bat/Gen
- Part time: 3,337 hours
- Stage of operation: IN
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/96ZZZX5943

## Discrepancy

LEFT HAND GENERATOR APPEARED TO CARRY ONLY 60 AMP LOAD.  TROUBLESHOT TO AN INDICATION ERROR.  FOUND BAT/GEN SWITCH TO CAUSE LEFT GENERATOR AMMETER INDICATION ERROR.  INSTALLED NEW SWITCH OPERATIONAL TEST GOOD.  THIS IS THE SECOND TIME THIS FACILITY HAS FOUND THIS PROBLEM.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.