# SDR 9700599501

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 11, 1997
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N95S](https://openairdocs.org/aircraft/N95S), registered now
- Make and model: Doug DC-9-15
- Registry model: [Doug DC-9-15](https://openairdocs.org/model/mcdonnell-douglas-dc-9-15) (OpenAirDocs)
- Aircraft serial: 47205
- System (JASC): [4930 · APU Engine Fuel and Control](https://openairdocs.org/jasc/4930)
- Part: Fuel Control
- Part number: 360231033
- Condition: Malfunctioned
- Location: Apu
- Part time: 27,943 hours
- Stage of operation: CL
- Nature of condition: O
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/9700599501

## Discrepancy

DURING CLIMB, APU AUTO SHUTDOWN.  NR 1 ENGINE GENERATOR ON MEL.  AIRCRAFT RETURNED TO DEPARTURE AIRPORT.  MAINTENANCE REPLACED THE APU FUEL CONTROL, LEAK CHECK GOOD.

---