## Discrepancy

ON CLIMBOUT, ENGINE NR 3 STRUT OVERHEAT LIGHT CAME ON.  COMPLETION OF RED TABS EXTINGUISHED LIGHT.  OPERATED NR 3 ENGINE WITH NO FURTHER ILLUMINATION OF LIGHT.  NR 3 BLEED AND NR 2 PACK TURNED OFF AND LEFT OFF PER RED TABS.  REMOVED PYLON PANELS 5501-5502 FROM RIGHT SIDE FOUND 8TH STAGE BLEED CHECK VALVE LEAKING DOWN STEAM SIDE OF VALVE.  INSTALLED 2 NEW GASKETS IN BLEED CHECK VALVE LEAK CHECKS GOOD RAN NR 3 ENGINE PER JET RUN HANDBOOK OPERATIONAL CHECKS GOOD.

---