# SDR 98FDEA00422

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 30, 1998
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N181FE](https://openairdocs.org/aircraft/N181FE), registered now
- Make and model: Boeing 727-22
- Registry model: [Boeing 727-22](https://openairdocs.org/model/boeing-727-22) (OpenAirDocs)
- Aircraft serial: 18868
- System (JASC): [3610 · Pneumatic Distribution System](https://openairdocs.org/jasc/3610)
- Part: Pack  Valve
- Condition: Leaking
- Location: Nr 1 Bleed
- Stage of operation: CL
- Nature of condition: J
- Precautionary procedure: H
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/98FDEA00422

## Discrepancy

CLIMBING THRU 17,000 LOWER AFT BODY HEAT LIGHT CAME ON.  COMPLIED WITH PROCEDURES.  LIGHT WENT OUT AFTER SECURING NR 1 BLEED.  LEAK BETWEEN PACK AND BLEED VALVE ON NUMBER 1 ACCORDING TO PROCEDURE.  RAN ENGINE DUPLICATING BLEED CONFIGURATION.  CHECKED DUCTING CLAMPS FOR SECURITY WITH NO LEAKS OR DEFECTS NOTED.  AFT BODY OVERHEAT LIGHT REMAINED EXTINGUISHED. OPERATIONAL CHECKS OK PER 26-14-00.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.