# SDR 98ZZZX1529

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 10, 1998
- Submitted: March 26, 2000
- Operation: General aviation
- Aircraft: [N143Z](https://openairdocs.org/aircraft/N143Z), registered now
- Make and model: Dhav DHC6300
- Aircraft serial: 437
- System (JASC): [2430 · DC Generating System](https://openairdocs.org/jasc/2430)
- Part: Circuit Breaker
- Part number: 12XRP12A1
- Condition: Failed
- Location: Battery
- Component: Ge
- Stage of operation: IN
- Nature of condition: W
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/98ZZZX1529

## Discrepancy

INSTALLED 'OVERHAULED' REVERSE CURRENT CIRCUIT BREAKER ON AIRCRAFT.  PLACED BATTERY SWITCH AND MASTER TO 'ON'.  BATTERY WOULD NOT COME ON LINE.  TROUBLESHOT SYSTEM AND FOUND AN 'OPEN' BETWEEN THE 'GENERATOR FIELD SWITCH TERMINALS'; THUS, NOT ALLOWING THE BATTERY RELAY TO BE ENERGIZED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.