# SDR 98ZZZX2828

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 15, 1998
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: N9307R
- Make and model: Doug DC-9-83
- Registry model: [Doug DC-9-83](https://openairdocs.org/model/douglas-dc-9-83) (OpenAirDocs)
- Aircraft serial: 49663
- System (JASC): [2420 · AC Generation System](https://openairdocs.org/jasc/2420)
- Part: Wire
- Condition: Worn
- Location: Generator
- Stage of operation: CR
- How discovered: O
- Nature of condition: K, H, J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/98ZZZX2828

## Discrepancy

THE LT GENERATOR TRIPPED OFF AND THERE WAS A LOSS OF LT HYDRAULIC SYSTEM FLUID.  FLT 249 MADE AN UNSCHEDULED LANDING AT MCI.  FOUND GENERATOR FEEDER CABLE RUBBED AN ELEVATOR RETURN HYDRAULIC LINE IN THE TAIL COMPARTMENT CAUSING FAILURE OF BOTH SYSTEMS.  REPLACED HYDRAULIC LINE AND SPLICED SECTION OF THE GENERATOR FEEDER CABLE.  CHECK-C 11-29-97 MCI.  REF:  OPERATOR CONTROL  NR TWAA9811401.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.