# SDR 99FDEA00050

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 5, 1999
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: 054FE
- Make and model: Doug DC-10-10F
- Registry model: [Doug DC-10-10F](https://openairdocs.org/model/mcdonnell-douglas-dc-10-10f) (OpenAirDocs)
- Aircraft serial: 47808
- System (JASC): [2612 · Fire Detection](https://openairdocs.org/jasc/2612)
- Part: Fire Detector
- Condition: Inop
- Location: Nr 2 Engine
- Stage of operation: CR
- Nature of condition: N
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/99FDEA00050

## Discrepancy

LOOP A LT ENG NR 2 ON S/O PANEL ALONG WITH NR 2 FIRE LT MASTER WARN AND FIRE LT ON FWD PNL.  *S/D*  REMOVED AND REPLACED BOTH NR 2 ENG AND APU FIRE BOTTLE PER MM 26-21-02-2.  REMOVED AND REPLACED PYLON A LOOP, BOLTS AND GASKETS ON TCC FLANGE.

---