# SDR 99FDEA00180

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 14, 1999
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N258FE](https://openairdocs.org/aircraft/N258FE), registered now
- Make and model: Boeing 727233
- Aircraft serial: 20940
- System (JASC): [2613 · Overheat Detection](https://openairdocs.org/jasc/2613)
- Part: Wire
- Condition: Out Of Position
- Location: Lwr Aft Body
- Stage of operation: CR
- How discovered: O
- Nature of condition: N
- Precautionary procedure: H
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/99FDEA00180

## Discrepancy

LWR AFT BODY O/H LIGHT.  TEST SYS OK PER RED TABS CLOSE BLD.  *S/D*  REPOSITIONED WIRE REF LOOP POS 26-14-1 PG 203.  REMOVED AND REPLACED MODULATING SHUT OFF VALVE PER MM 36-12-042-4.  LEAK CK OK.

---