## Discrepancy

NR 1 ENG STRUT FLICKERED ON T/O ROLL MOMENTARILY AND THEN EXTINGUISH AT 4,000' ALT, LIGHT ILLUM STEADY.  *S/D*  REMOVED AND REPLACED OVERHEAT LOOP PER MM 26-14-1, LEAK CK NORMAL.  LIGHT OPER CK NORM.  OK FOR SERVICE.

---