# SDR 99ZZZX2614

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 1, 1999
- Submitted: March 26, 2000
- Operation: General aviation
- Make and model: Cessna 172
- Registry model: [Cessna 172](https://openairdocs.org/model/cessna-172) (OpenAirDocs)
- System (JASC): [2432 · Battery/Charger System](https://openairdocs.org/jasc/2432)
- Part: Wire
- Condition: Corroded
- Location: Battery
- Stage of operation: NR
- How discovered: O
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/99ZZZX2614

## Discrepancy

NO CHARGING INDICATION.  FOUND BATTERY WIRE TO BUS BAR FROM REGULATOR PREVIOUSLY SPLICED.  SPLICE HEATED, CORRODED CAUSING LARGE RESISTANCE.  NOTED POWER TO REGULATOR WHEN STATIC ON THIS WIRE WHEN RUNNING POWER, WOULD NOT RETURN THROUGH THIS WIRE TO BUS.  WIRE ORIGINAL, SPLICED?

---