# SDR 99ZZZX966

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 27, 1999
- Submitted: March 26, 2000
- Operation: General aviation
- Aircraft: N375ES
- Make and model: Cessna 172R
- Registry model: [Cessna 172R](https://openairdocs.org/model/cessna-172r) (OpenAirDocs)
- Aircraft serial: 17280057
- System (JASC): [3411 · Pitot/Static System](https://openairdocs.org/jasc/3411)
- Part: Connector
- Part number: S11332
- Condition: Misinstalled
- Location: Pitot Tube
- Part time: 196 hours
- Stage of operation: IN
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/99ZZZX966

## Discrepancy

PERFORMED STATIC LEAK CHECK PER SB 97-32-02R1, ALT STATIC VALVE REPLACEMENT.  STATIC CHECK FAILED DUE TO CROSS-THREADED CONNECTOR INTO PITOT TUBE ITEM 41 AND CROSS-THREADED B-NUT ITEM 42 OF IPC (34-11-00-01).  REPLACED BOTH CONNECTORS.  OPS CHECKS NORMAL.  SUBMITTER RECOMMENDATION TO PREVENT RECURRENCE; HAVE IT INSTALLED CORRECTLY AT CESSNA AIRCRAFT.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.