## Discrepancy

DURING CLIMB, HYDRAULIC NR 3 LOW PRESSURE MESSAGE APPEARED AND 0 PSI WAS INDICATED.  FOUND 3A PUMP CIRCUIT BREAKER 2G15 POPPED, RESET ONCE, LOW PRESSURE MESSAGE CLEARED.  ON GROUND, FOUND CB2N12 TO BE POPPED (HYD SYSTEM IND 3) TRIED ONE RESET C/B WOULD NOT RESET.  CLEANED CONNECTOR ON HYD PRESSURE TRANSDUCER NR 3, RESET CB 2N12.  OPS CHECK GOOD IAW AMM 29-10-00.  NO DEFECTS NOTED AT THIS TIME.  (M)

---