# SDR A6WA2018012445588

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 21, 2018
- Submitted: January 24, 2018
- Operation: Air carrier
- Aircraft: [N413AW](https://openairdocs.org/aircraft/N413AW), registered now
- Make and model: Cndair CL6002B19
- Aircraft serial: 7585
- Aircraft time: 37,123 hours, 34,873 cycles
- System (JASC): [2420 · AC Generation System](https://openairdocs.org/jasc/2420)
- Part: Control Unit
- Condition: Malfunctioned
- Location: Adg
- Stage of operation: CL
- How discovered: O
- Nature of condition: H
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/A6WA2018012445588

## Discrepancy

AFTER TAKEOFF,  THE AIR DRIVEN GENERATOR DEPLOYED UNCOMMANDED. COMPLIED WITH QRH,  GENERATORS DID NOT PICK UP THE LOAD, AND POWER TRANSFER OVERRIDE SWITCH DID NOT WORK. DIVERTED.  THE GENERATOR TRANSFER OCCURRED BELOW 80 KNOTS AFTER LANDING.  REPLACED ADG AUTO DEPLOY CONTROL PANEL UNIT.  CHECKED GOOD.  REPLACED CONTROL PANEL  CONNECTOR.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.