# SDR AALA20060314

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 19, 2006
- Submitted: May 26, 2006
- Operation: Air carrier
- Aircraft: [N226AA](https://openairdocs.org/aircraft/N226AA), registered now
- Make and model: Doug DC-9-82
- Registry model: [Doug DC-9-82](https://openairdocs.org/model/mcdonnell-douglas-dc-9-82) (OpenAirDocs)
- Aircraft serial: 49176
- System (JASC): [2822 · Fuel Boost Pump](https://openairdocs.org/jasc/2822)
- Part: Pump
- Part number: 3980001
- Condition: Inoperative
- Location: Fuel Boost
- Stage of operation: CL
- How discovered: V
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/AALA20060314

## Discrepancy

DFW - CENTER FUEL TANK TRANSFER PROBLEM.  RETURNED TO DFW AND LANDED WITHOUT INCIDENT.  FOUND CENTER FUEL BOOST PUMP CIRCUIT BREAKER TRIPPED.  REPLACED CENTER TANK FORWARD BOOST PUMP.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.