# SDR AALA2009012700245

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 27, 2009
- Submitted: April 29, 2009
- Operation: Air carrier
- Aircraft: [N9615W](https://openairdocs.org/aircraft/N9615W), registered now
- Make and model: Doug DC-9-83
- Registry model: [Doug DC-9-83](https://openairdocs.org/model/douglas-dc-9-83) (OpenAirDocs)
- Aircraft serial: 53562
- Aircraft time: 34,361 hours, 16,135 cycles
- System (JASC): [2450 · AC Power Distribution System](https://openairdocs.org/jasc/2450)
- Part: Circuit Breaker
- Condition: Failed
- Location: Zone 100
- Stage of operation: CL
- How discovered: O
- Nature of condition: H
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/AALA2009012700245

## Discrepancy

ORD INFLIGHT - DURING CLIMB CENTER TANK PRESSURE INDICATOR LIGHT ILLUMINATED ON OVERHEAD PANEL.  LANDED ORD WITHOUT INCIDENT.  FOUND THREE FUEL PUMP CIRCUIT BREAKERS POPPED.  REPLACED LEFT AC PHASE C CIRCUIT BREAKER B1743.  SYSTEM GROUND CHECKED NORMAL OPERATION.

---