# SDR AALA20120309022

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 9, 2012
- Submitted: March 14, 2012
- Operation: Air carrier
- Aircraft: N9404V
- Make and model: Doug DC-9-83
- Registry model: [Doug DC-9-83](https://openairdocs.org/model/douglas-dc-9-83) (OpenAirDocs)
- Aircraft serial: 53140
- Aircraft time: 55,259 hours, 26,545 cycles
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Control Valve
- Condition: Inoperative
- Location: Ac Bay
- Stage of operation: CL
- How discovered: O
- Nature of condition: O
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/AALA20120309022

## Discrepancy

DFW - CREW REPORTED PRESSURIZATION ISSUES ON CLIMBOUT.  EMERGENCY DECLARED FLIGHT RETURNED DFW LANDED WITHOUT INCIDENT.  AIRCRAFT REMOVED FROM SERVICE.  REPLACED RIGHT AND PACK FLOW CONTROL VALVE.  SYSTEM GROUND CHECK NORMAL OPERATION.

---