# SDR AALA202004039002

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 2, 2020
- Submitted: April 3, 2020
- Operation: Air carrier
- Aircraft: N955UW
- Make and model: Emb ERJ 190-100 IGW
- Registry model: [EMB ERJ 190-100 IGW](https://openairdocs.org/model/embraer-erj-190-100-igw) (OpenAirDocs)
- Aircraft serial: 19000152
- Aircraft time: 25,521 hours, 21,388 cycles
- System (JASC): [5210 · Passenger/Crew Doors](https://openairdocs.org/jasc/5210)
- Part: Pneumatic System
- Condition: Low Pressure
- Location: L2 Door
- Stage of operation: IN
- How discovered: C
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/AALA202004039002

## Discrepancy

AIRCRAFT IN BASE MAINTENANCE: DURING CHECK OF CABIN DOOR EMERGENCY PNEUMATIC ASSEMBLY, FOUND L2 DOOR UNDER DISPATCH LIMITS. MAINTENANCE SERVICED PNEUMATIC ASSEMBLY TO PROPER PRESSURE PER AMM 52-41-51-614-801-A AND 52-12-51-614-802-A.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.