# SDR AALA202608065063

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 3, 2026
- Submitted: August 6, 2026
- Operation: Air carrier
- Aircraft: [N711UW](https://openairdocs.org/aircraft/N711UW), registered now
- Make and model: Airbus A319-112
- Registry model: [Airbus A319-112](https://openairdocs.org/model/airbus-industrie-a319-112) (OpenAirDocs)
- Aircraft serial: 1033
- Aircraft time: 71,398 hours, 42,124 cycles
- System (JASC): [3350 · Emergency Lighting](https://openairdocs.org/jasc/3350)
- Part: Elec Connector
- Condition: Not Seated
- Location: Zone 200
- Stage of operation: IN
- How discovered: C
- Nature of condition: L
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/AALA202608065063

## Discrepancy

AIRCRAFT IN BASE MAINTENANCE: EMERGENCY LIGHTS TEST SHOWS FAULT EMERGENCY POWER SUPPLY UNIT COMMUNICATION AFT LEFT - MAINTENANCE CHECKED EMERGENCY POWER SUPPLY UNIT CONNECTION AND RECONNECTED PER TSM 33-51-00-810 WHICH RESLUTED IN THE FAULT BEING CLEARED

---