# SDR AALA991383

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 11, 1999
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: N164AA
- Make and model: Doug DC-10-30
- Registry model: [Doug DC-10-30](https://openairdocs.org/model/mcdonnell-douglas-dc-10-30) (OpenAirDocs)
- Aircraft serial: 46950
- System (JASC): [2916 · Hydraulic Reservoir, Main](https://openairdocs.org/jasc/2916)
- Part: Reservoir
- Part number: AYG70275015
- Condition: Defective
- Location: Nr 3 Hyd System
- Stage of operation: CR
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/AALA991383

## Discrepancy

DFW - FLT 5 - AFTER TAKEOFF DFW-HNL, NR 3 HYDRAULIC TEMPERATURE REACHED 103 DEGREES AND CONTINUED TO CLIMB WITH BOTH ENGINE DRIVEN PUMPS OFF AND THE 2-3 REVERSIBLE PUMP OPERATING.  AIRCRAFT RETURNED TO DFW, DUMPED FUEL, AND LANDED WITHOUT INCIDENT.  REPLACED NR 3 HYDRAULIC RESERVOIR.  SYSTEM GROUND CHECKED NORMAL OPERATION.  (M)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.