# SDR ABXA20260315103

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 15, 2026
- Submitted: March 16, 2026
- Operation: Air carrier
- Aircraft: [N391CM](https://openairdocs.org/aircraft/N391CM), registered now
- Make and model: Boeing 767381
- Aircraft serial: 32975
- Aircraft time: 60,067 hours, 24,531 cycles
- System (JASC): [3030 · Pitot/Static Anti-Ice System](https://openairdocs.org/jasc/3030)
- Part: Pitot Tube
- Part number: 0856LU4
- Part serial: 270960
- Condition: Defective
- Location: Zone 200
- Part time: 20,966 hours, 6,489 cycles
- Stage of operation: TX
- How discovered: O
- Nature of condition: J
- Precautionary procedure: D
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ABXA20260315103

## Discrepancy

DURING TAXI OUT, F/O PITOT EICAS MSG AFTER RIGHT ENG START.  A/C RETURNED TO GATE (BTB). MTX GROUNDED A/C.  MTX REMOVED AND REPLACED R/H UPPER PITOT PROBE WITH A NEW QICK DISCONNECT PITOT PROBE IAW B767 AMM 34-11-01. PITOT HEAT TEST SWITCH CHECK GOOD.  NO MAINTENANCE MESSAGES AT THIS TIME. SEALANT APPLIED AT 1700Z 15 MAR 26. A/C REMAINS ETOPS 180. A/C RETURNED TO SERVICE.

---