# SDR ABXA20260707308

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 7, 2026
- Submitted: July 7, 2026
- Operation: Air carrier
- Aircraft: [N763CK](https://openairdocs.org/aircraft/N763CK), registered now
- Make and model: Boeing 767-3P6
- Registry model: [Boeing 767-3P6](https://openairdocs.org/model/boeing-767-3p6) (OpenAirDocs)
- Aircraft serial: 26233
- Aircraft time: 93,741 hours, 30,324 cycles
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Warning Message
- Condition: False Activation
- Location: Hyd Shutoff Vlv
- Stage of operation: TX
- How discovered: O
- Nature of condition: N
- Precautionary procedure: D
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ABXA20260707308

## Discrepancy

RT WING HYD VALVE EICAS MSG DISPLAYED DURING TAXI. ACFT RETURNED TO THE GATE (BTB) AND MTX GROUNDED ACFT. MTX PERFORMED OPS CHECK OF RT WING HYD SHUTOFF VALVE IAW AMM 27-13-04. OPS CHECK GOOD. RETURNED ACFT TO SERVICE .

---