# SDR ABXA9500216

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 16, 1995
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: N954AX
- Make and model: Doug DC-9-41
- Registry model: [Doug DC-9-41](https://openairdocs.org/model/douglas-dc-9-41) (OpenAirDocs)
- Aircraft serial: 47612
- System (JASC): [2420 · AC Generation System](https://openairdocs.org/jasc/2420)
- Part: Wire
- Condition: Burned
- Location: Ac Gen Syst
- Stage of operation: TX
- How discovered: O
- Nature of condition: H, B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ABXA9500216

## Discrepancy

RIGHT GENERATOR DROPPED OFF LINE WITH CROSS-TIE LOCKOUT.  SMOKE IN THE COCKPIT REPORTED.  FOUND GENERATOR FEEDER CABLES OVERHEATED BEHIND THE GENERATOR CONTROL PANEL.  REPLACED TERMINAL ON MAIN FEEDER CABLE.  REPLACED  CABLE FROM TERMINAL STRIP TO GENERATOR RELAY.  OPS CHECKED GOOD IAW DC-9 M.M. CHAPTER 24.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.