# SDR ABXA9500574

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 10, 1995
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N850AX](https://openairdocs.org/aircraft/N850AX), registered now
- Make and model: Doug DC-8-61
- Registry model: [Doug DC-8-61](https://openairdocs.org/model/douglas-dc-8-61) (OpenAirDocs)
- Aircraft serial: 45894
- System (JASC): [2780 · Leading Edge Slat Control System](https://openairdocs.org/jasc/2780)
- Part: Packing
- Part number: 37155495501
- Condition: Leaking
- Location: Slot Contl Vlv
- Stage of operation: CL
- Nature of condition: K, J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ABXA9500574

## Discrepancy

ON CLIMB-OUT OF ONT, HYDRAULIC QUANTITY LOSS AND PRESSURE  OF ZERO WAS INDICATED.  RESERVOIR LOW PRESSURE LIGHT ILLUMINATED AT 6 GALLONS HYDRAULIC QUANTITY.  REPACKED SLOT CONTROL VALVE.  ALSO, REMOVED AND REPLACED NR 1 AND NR 2 HYDRAULIC PUMPS AND FILTERS IAW DC 8 MM.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.