# SDR AC2A2021061013901

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 24, 2021
- Submitted: June 10, 2021
- Operation: Air carrier
- Aircraft: [N139FW](https://openairdocs.org/aircraft/N139FW), registered now
- Make and model: Agusta AB139
- Registry model: [Agusta AB139](https://openairdocs.org/model/agusta-ab139) (OpenAirDocs)
- Aircraft serial: 31022
- Aircraft time: 7,773 hours, 15,665 cycles
- System (JASC): [6322 · Rotorcraft Cooling Fan System](https://openairdocs.org/jasc/6322)
- Part: Cooling Fan
- Part number: 3G6320V03853
- Part serial: 141600806
- Condition: Leaking
- Part time: 2,049 hours, 3 cycles
- Stage of operation: IN
- How discovered: V
- Nature of condition: K
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/AC2A2021061013901

## Discrepancy

OIL COOLER FAN WAS REMOVED AND REPLACED DUE TO MGB FAN QUILL SEAL LEAKING ALLOWING OIL TO MIGRATE TO FAN BEARINGS.  TEARDOWN REPORT INDICATES BEARINGS WORN AND REPLACED WITH ONLY 284.4 HOURS SINCE OVERHAUL.

---