# SDR AMTA200700049

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 1, 2007
- Submitted: February 8, 2007
- Operation: Air carrier
- Aircraft: [N517AT](https://openairdocs.org/aircraft/N517AT), registered now
- Make and model: Boeing 757-23N
- Registry model: [Boeing 757-23N](https://openairdocs.org/model/boeing-757-23n) (OpenAirDocs)
- Aircraft serial: 27973
- System (JASC): [3600 · Pneumatic System](https://openairdocs.org/jasc/3600)
- Part: Valve
- Part number: 3964801
- Part serial: 1594
- Condition: Unserviceable
- Location: Rt Bleed Sys
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/AMTA200700049

## Discrepancy

EICAS MSG R ENG BLEED OFF DISPLAYED R ENG BLEED OFF LIGHT ILLUMINATED, CUICT PRESS NO RM 2119Z.  REMOVED AND REPLACED FLOW CONTROL AND SHUTOFF VALVE PER AMM 21-51-01-2.  RAN ENGINE, OPS CHECK NORMAL.  (M)

---