# SDR ANCF200800009

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 5, 2008
- Submitted: May 8, 2008
- Operation: Air carrier
- Aircraft: [N521NA](https://openairdocs.org/aircraft/N521NA), registered now
- Make and model: Boeing 757236
- Aircraft serial: 25592
- Aircraft time: 49,826 hours, 16,346 cycles
- System (JASC): [3097 · Ice/Rain Protection System Wiring](https://openairdocs.org/jasc/3097)
- Part: Cable
- Condition: Overheated
- Location: Window Heat
- Stage of operation: CR
- How discovered: O
- Nature of condition: M, B
- Precautionary procedure: H
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ANCF200800009

## Discrepancy

WINDOW HEAT CABLES OF L SIDE WINDOW OVERHEATED PRODUCING FUMES L SIDE WINDOW HEAT SW WAS TURNED OFF.  DEFERRED TO DMI LOG BOOK ITEM NR 307 WAS INSPECTED L SIDE WINDOW POWER LINES AND FOUND BURNT.  DUE THIS CONDITION L SIDE WINDOW HEATING IS DEACTIVATED AND DEFERRED TO MEL.    INSPECTED L SIDE WINDOW POWER LINES AND FOUND BURNED.  WINDOW HEATING DEACTIVATED AND DEFERRED TO MEL MAINTENANCE PROCEDURES ACCOMPLISHED. IAW AMM  56-11-02 OPENABLE WINDOW  N2  LT  WAS REPLACED OPERATIONAL TEST SATISFACTORY.

---