- Aircraft: N906R
- Make and model: Doug DC-8-63F
- Registry model: [Doug DC-8-63F](https://openairdocs.org/model/mcdonnell-douglas-dc-8-63f) (OpenAirDocs)
- Aircraft serial: 46087
- Aircraft time: 79,414 hours, 26,483 cycles
- System (JASC): [2997 · Hydraulic Power System Wiring](https://openairdocs.org/jasc/2997)
- Part: Connector
- Condition: Dirty
- Location: Hyd Reservior
- Stage of operation: TX
- How discovered: O
- Nature of condition: N
- Precautionary procedure: D
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ARWA20060203

## Discrepancy

BLOCK TURNBACK PRIOR TO TAKEOFF DUE TO HYDRAULIC QUANTITY LOSS.  CHECKED HYDRAULIC RESERVOIR, FOUND FULL; CLEANED CONNECTOR AT HYDRAULIC QUANTITY TRANSMITTER IN ACCORDANCE WITH M/M 20-50-1; CHECKED HYDRAULIC QUANTITY, FOUND NORMAL READING.

---