# SDR ARWA20070803

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 22, 2007
- Submitted: August 27, 2007
- Operation: Air carrier
- Aircraft: N68041
- Make and model: Doug DC-10-10
- Registry model: [Doug DC-10-10](https://openairdocs.org/model/mcdonnell-douglas-dc-10-10) (OpenAirDocs)
- Aircraft serial: 46900
- Aircraft time: 91,256 hours, 33,973 cycles
- System (JASC): [3097 · Ice/Rain Protection System Wiring](https://openairdocs.org/jasc/3097)
- Part: Connector
- Condition: Damaged
- Location: Heater Control
- Stage of operation: CR
- How discovered: O
- Nature of condition: B, J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ARWA20070803

## Discrepancy

LEFT STATIC PORT HEAT AND RIGHT STATIC PORT HEAT AND LEFT ANGLE OF ATTACK C/B`S POPPED WITH LIGHT SMOKE FROM AROUND THE FIRE HANDLES.  REMOVED AND REPLACED CONNECTOR FROM HEATER CONTROLLER IN ACCORDANCE WITH M/M 20-30-02, AND REMOVED AND REPLACED HEATER CONTROLLER MONITOR IN ACCORDANCE WITH M/M 30-35-01.  OPERATIONAL CHECK NORMAL IN ACCORDANCE WITH M/M 30-30-00.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.