# SDR ARWA981211

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 19, 1998
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: N802BN
- Make and model: Doug DC-8-62
- Registry model: [Doug DC-8-62](https://openairdocs.org/model/mcdonnell-douglas-dc-8-62) (OpenAirDocs)
- Aircraft serial: 45909
- System (JASC): [3030 · Pitot/Static Anti-Ice System](https://openairdocs.org/jasc/3030)
- Part: Pitot Tube
- Part number: 8J1CU1
- Condition: Inop
- Location: Fuselage
- Stage of operation: IN
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ARWA981211

## Discrepancy

F/O PITOT HEAT INOP.  REMOVED AND REPLACED CURRENT DETECTOR IAW DC-8 M/M 30-30-0.  NO HELP.  REMOVED AND REPLACED F/O PITOT TUBE IAW DC-8 M/M 30-30-0.  PERFORMED PITOT STATIC LEAK CHECK IAW DC-8 M/M 34-12-0.  OPERATION NORMAL.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.