ON CLIMBOUT, RT PACK LIGHT ILLUMINATED.  QRH CHECKLIST ACCOMPLISHED & PACK RESET BUT FOR ONLY ABOUT 1 MINUTE.  RAN CHECKLIST 1 MORE TIME & THIS CAUSED BLEED TRIP OFF LIGHT TO ILLUMINATE.  RAN QRH & BLEED TRIP RESET BUT CAUSED PACK TO TRIP AGAIN.  AT THAT POINT RAN QRH & ISOLATED RT PACK.  DUCT PRESSURE NORMAL EXCEPT DURING BLEED TRIP OFF.  FOUND BAD, R & R NR 2 ENGINE PRECOOLER CONTROL VALVE.  FOUND BAD,  R & R NR 2 ENGINE BLEED AIR REGULATOR.  ALT PROCEDURE:  POWER REMOVED FROM ACFT & THEN RE-INSTALLED W/OPS AND LEAK CHECK GOOD.  R & R PRECOOLER CONTROL VALVE SENSOR

---