## Discrepancy

WHILE ACCOMPLISHING T/C 78273000,  INTERROGATE THE FMC CDU FOR ENGINE FAULTS.   FOUND FAULT CODE 75-10831 THE T3 SIGNAL IS OUT OF RANGE. (LONG TIME FAULT).  ACFT GROUNDED. FAULT NOT ACTIVE NO RECENT OR FAULT HISTORY. VERFIED T3 CHANNEL A & CHANNEL B DATA DISPLAYED. CLEANED DP0905 & DP1005 CONNECTORS, VERIFIED GOOD PIN TENSION RESISTANCE CHECKED T3 SENSOR CHANNEL A 3.1, CHANNEL B 3.0 OHM. REINSTALLED CONNECTORS REPAIR CONFIRMED. FAULT INTERMITTENT AT TIME OF WRITE UP. REF FIM 75-33-00-810-802-F00.

---