# SDR ASAA2016111918736

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 19, 2016
- Submitted: November 21, 2016
- Operation: Air carrier
- Aircraft: [N462AS](https://openairdocs.org/aircraft/N462AS), registered now
- Make and model: Boeing 737990ER
- Aircraft serial: 36362
- Aircraft time: 10,202 hours, 3,319 cycles
- System (JASC): [2160 · Cabin Temperature Control System](https://openairdocs.org/jasc/2160)
- Part: Filter
- Part number: 6240181
- Condition: Clogged
- Location: Cabin
- Stage of operation: CR
- How discovered: O
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ASAA2016111918736

## Discrepancy

UNABLE TO CONTROL CABIN TEMP. STARTED OUT HOT, ADJUSTED TEMP VERY SMALL AMOUNT ON AFT CABIN CONTROL. CABIN WENT TOO COLD. READJUSTED TOWARD WARM, GOT REALLY HOT. RAN CABIN HOT QRH, TURNED OFF TRIM AIR SWITCH. CABIN TEMP CONTROL WENT BACK TO NORMAL. GROUNDED, YES. CLEANED ALL 3 CABIN & FLIGHT DECK TEMP SENSOR FILTERS, REF B737-900 AMM 21-61-06-100-801. ACCOMPLISHED CABIN TEMPERATURE CONTROL & INDICATION OPS TEST, TEST PASS, NO FAULTS NOTED, REF AMM 21-61-00-700-807-002. TRIM AIR SWITCH ON.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.