# SDR ASOA200801359

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 16, 2008
- Submitted: October 21, 2008
- Operation: Air carrier
- Aircraft: N971EV
- Make and model: Cndair CL6002B19
- Aircraft serial: 7528
- Aircraft time: 16,593 hours, 13,869 cycles
- System (JASC): [5315 · Fuselage Main, Floor Beam](https://openairdocs.org/jasc/5315)
- Part: Floorbeam
- Condition: Corroded
- Location: Fuselage
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ASOA200801359

## Discrepancy

FLOORBEAM AT LBL 9 FS 589 TO FS 621 HAS CORROSION ON OUTBOARD FLANGE FLOORBOARD ATTACH HOLES.  REMOVED FLOORBEAM CAP AT LBL 9, FS 589 TO FS 621 IAW SRM 51-42-06 AND 51-42-21.  DRILLED NEW SERVICEABLE FLOORBEAM CAP IAW SRM 51-40-11. OK TO INSTALL. INSTALLED NEW SERVICABLE BEAM CAP IAW SRM 51-42-06 AND 51-42-21 AND 51-42-28.   REINSTALLED SERVICEABLE LOWER WEB.  INSTALLED ALTERNATE FASTENERS IN FLOORBEAM CAP IAW REO 601R-53-61-2849.  EC/TC REO 601R-53-61-2849 INCORPORATED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.